Honeywell R8182D1079 Combination Protector Relay & Hydronic Heating Control w/ High Limit: 10 F fixed, Low Limit/Circulator (10F to 25F)
- SKU: R8182D1079
- Brand: Honeywell
$1,198.40
Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems.
refund
On orders over $99
Features:
- Use in intermittent ignition applications.
- Capable of zone control with zone valves.
- Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8 Flame failure during the running cycle results in a 45 second attempt to restart.
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.
- R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.
- C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.
- Description: Combination Protectorelay and Hydronic Heating Control with High limit: 10 F fixed; low limit/circulator: 10 F to 25 F adj. Differential
- Switching Action: SPST
- Operating Range, Low Limit (F): 110 to 220 F
- Operating Range, High Limit (F): 130 to 240 F
- Differential Temperature: High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj.
- Anticipator Setting: .2A
- Maximum Safe Operating Pressure (psi): 200 psi on immersion well; 100 psi direct immersion.
- Electrical Rating (ignition): 360 VA
- Electrical Ratings (burner AFL): 4.4 A @ 120 Vac
- Voltage: 120 Vac
- Frequency: 60 Hz
- Timing Safety Switch: 45 sec
- Maximum Power Consumption: 9W
- Dimensions: 7 1/8 in. high x 5 1/4 in. wide x 3 7/16 in. deep.
- Insulation Depth (in.): 1-1/2 inch
- Mounting: Vertical Mount
- Operating Humidity Range: 0 to 95% RH, non-condensing
- Max Ambient Temp: 250 F at element
- Includes: Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case
| Weight | 10 lbs |
|---|---|
| Brand | |
| Attachments | Installation Instruction R8182D,H, Specification R8182D,E,F,H,J |
Only logged in customers who have purchased this product may leave a review.
Download PDF
Download PDF
Related products
-
Remove from Wishlist
SKU:5335
4 Zone Expandable Switching Relay w/ Priority (ZSR104)
$259.91Add to cartThe ZSR series is a zone pump and boiler operating control for multiple zone hydronic heating systems. The ZSR series interfaces with low voltage thermostats, or any other low voltage controllers having a switching action.
-
Remove from Wishlist
SKU:600
Standard Pilot Gas Valve – 24V – 3/4″ x 3/4″ Inlet/Outlet Size (Model V800A1591)
$439.00Add to cartUsed on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, and pressure regulator, pilot gas filter and flow adjustment, pressure tapping, and thermocouple connector.
- Remove from Wishlist
- Remove from Wishlist
- Remove from Wishlist
- Remove from Wishlist
- Remove from Wishlist
-
Remove from Wishlist
SKU:657
Standard Pilot Gas Valve – 120 Vac
$281.11Read moreUsed on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, and pressure regulator, pilot gas filter and flow adjustment, pressure tapping, and thermocouple connector.
- Remove from Wishlist
- Remove from Wishlist














Reviews
There are no reviews yet.